Explore our beta site

Are you an Industrial Manufacturing or Industrial Maintenance and Repair professional? Explore our brand-new beta site for a customized experience. 

Browse Now

LOCTITE® 510 - Tube 10.0/case High Temperature Gasket Sealant

Known as Loctite 510 Gasket Eliminator Flange Sealant

Features and Benefits

Available sizes:

This form-in-place anaerobic-curing gasketing sealant provides high temperature and chemical resistance on close fitting, rigid machined metal flanges.
LOCTITE® 510 is a high-temperature resistant, form-in-place anaerobic-curing sealant, which forms an instant, low-pressure seal when confined in the absence of air between close fitting metal surfaces. Ideal for rigid flanges, especially in transmissions and motor casings. Unprimed gap-fill is 0.25 mm (0.01"). Recommended for use with aluminum and steel substrates.
  • For close fitting, rigid metal flanges
  • Temperature resistant up to 204°C (400°F)
  • Adapts to surface irregularities and scratches up to 0.01" (0.25mm)
  • Increases torque capacity of assembled flanges
  • Registered to NSF Category P1
Read More

Documents and Downloads

Safety Data Sheets and RoHs
LOCTITE® 510, 50 ml Tube 135474 en-US
IDH: 135474
EAN: 079340510319

Size Case: Tube

Quantity: 10.0/case

No documents found

Technical Information

Application method Dispense system, Manual, Screen printing
Applications For close fitting parts, For high temperature applications, Rigid assembly gasketing, Sealing
Chemical basis / base Dimethacrylate ester
Color Pink
Cure type Anaerobic cure
Fixture time, Steel 25.0 min.
Gap fill, Unprimed 0.25 mm
Key characteristics Chemical resistant, For machined, rigid flanges, Strength: medium strength, Thixotropic
Number of components 1 part
Operating temperature -65.0 - 400.0 °F (-55.0 - 200.0 °C )
Physical form Gel
Recommended for use with Metal: aluminum, Metal: steel
Storage temperature 8.0 - 21.0 °C
Viscosity, 20 RPM 90000.0 mPa·s (cP)

How to

Step by Step Guide

1. Preparation - Cleaning

For gasket repair applications only: Apply LOCTITE® SF 790 to old gasket or gasket sealants and use a wood or plastic scraper to remove residues from flange surfaces. Remove burrs. It is recommended to use LOCTITE® SF 7070 to degrease and clean surfaces prior to applying the sealant. For serial production make sure that surfaces are free of contaminations.

2. Preparation - Activation

If cure speed of LOCTITE® 510 is too slow due to passive metals or low temperature (below 5°C), use LOCTITE® SF 7649 activator. Allow to dry.

3. Application

Apply a continuous bead of sealant onto one flange surface. Place the bead close to the inner rim of the flange and encircle all bolt holes. Small surface scratches will be filled by the adhesive. LOCTITE® 510 can also be applied by roller onto larger flanges.

4. Assembly

Assemble flanges and tighten bolts as soon as possible. Wipe away any excess squeeze-out, as this will not cure when exposed to air due to the sealant's anaerobic curing properties.

5. Disassembly

Disassemble bolts with standard hand tools. Use jacking-screws, cast-on bosses or recesses to lift flanges apart. Once disassembled, apply LOCTITE® SF 790 on old sealant and use a wood or plastic scraper to remove residues from flange surfaces.

Frequently Asked Questions