LOCTITE® 518 - Bottle 12.0/case Gasket Sealant
Known as Loctite 518 Gasket Eliminator Flange Sealant
Features and Benefits
Product image in this size is not available.
Available sizes:
- Semi-flexible anaerobic flange sealant
- Adapts to surface irregularities & gap fill up to 0.01" (0.25mm)
- Forms an instant low-pressure seal
- Cures on inactive surfaces without primer
- NSF registered
Documents and Downloads
- Bottle 12.0/case - IDH 2392164
Size Case: Bottle
Quantity: 12.0/case
Looking for a TDS or SDS in another language?
Additional Documents
Technical Information
Application method | Dispense system, Manual |
Applications | Rigid assembly gasketing, Sealing |
Chemical basis / base | Dimethacrylate ester |
Color | Red |
Cure type | Anaerobic cure |
Fixture time, Steel | 25.0 min. |
Gap fill, Unprimed | 0.25 mm |
Key characteristics | Fluorescent, For machined, rigid flanges, Immediate low pressure sealing, Strength: medium strength, Surface contamination-tolerant, Thixotropic |
Number of components | 1 part |
Operating temperature | -55.0 - 150.0 °C (-65.0 - 300.0 °F ) |
Physical form | Gel |
Recommended for use with | Metal: aluminum, Metal: iron - cast iron, Metal: passive metal, Metal: steel |
Specific gravity, @ 25.0 °C | 1.1 |
Storage temperature | 8.0 - 21.0 °C |
Viscosity | 750000.0 mPa·s (cP) |
How to
Step by Step Guide
1. Preparation - Cleaning
Apply LOCTITE® SF 790 to old gasket or gasket sealants and use a wood or plastic scraper to remove residues from flange surfaces. Remove burrs. It is recommended to use LOCTITE® SF 7070 to degrease and clean surfaces prior to applying the sealant.
2. Preparation - Activation
If cure speed of LOCTITE® 518 is too slow due to passive metals or low temperature (below 5°C), use LOCTITE® SF 7649 activator. Allow to dry.
3. Application
Apply a continuous bead of sealant onto one flange surface. Place the bead close to the inner rim of the flange and encircle all bolt holes. Small surface scratches will be filled by the adhesive. LOCTITE® 518 can also be applied by roller onto larger flanges.
4. Assembly
Assemble flanges and tighten bolts as soon as possible. Wipe away any excess squeeze-out, as this will not cure when exposed to air due to sealant's anaerobic curing properties.
5. Disassembly
Disassemble bolts with standard hand tools. Use jacking-screws, cast-on bosses or recesses to lift flanges apart. Once disassembled, apply LOCTITE® SF 790 on old sealant and use a wood or plastic scraper to remove residues from flange surfaces. For corroded or seized parts, use LOCTITE® LB 8040 Freeze and Release.